Technical Summary
| Motor type | Permanent-magnet synchronous motor; High Dynamic |
|---|---|
| Rated power | PN=2 kW |
| DC-link voltage | UDC=600 V |
| Rated speed | 3,000 rpm (100 K) |
| Rated torque | 6.5 Nm (100 K) |
| Encoder | Absolute Encoder single-turn 24 bits, Encoder AS24DQI, with DRIVE-CLiQ interface |
| Cooling | Natural cooling |
| Mounting | IM B5 (IM V1, IM V3) |
| Protection | IP64 |
| Shaft | Plain shaft, tolerance N |
| Holding brake | without holding brake |
Key Features
PN=2 kW; rated speed: 3,000 rpm (100 K); rated torque: 6.5 Nm (100 K).
Rated current: 7.0 A; maximum current: 84.0 A; UDC=600 V.
Absolute Encoder single-turn 24 bits, Encoder AS24DQI, with DRIVE-CLiQ interface.
Design acc. to Code I: IM B5 (IM V1, IM V3); M40 connector size; rotatable connectors for signals and power.
Natural cooling and degree of protection IP64.
Plain shaft with tolerance N; without holding brake; radial runout tolerance: 0.050 mm.
Frequently Asked Questions
What are the rated power, voltage, speed, and torque of 1FK7085-4CF71-1BG0?
PN=2 kW, UDC=600 V, rated speed is 3,000 rpm (100 K), and rated torque is 6.5 Nm (100 K).
Which Encoder does this motor have?
It has an absolute Encoder AS24DQI, single-turn 24 bits, with DRIVE-CLiQ interface.
How is the motor mounted and connected?
It uses design acc. to Code I IM B5 (IM V1, IM V3), an M40 connector size, and rotatable connectors for signals and power.
What cooling and protection does it provide?
It has natural cooling and degree of protection IP64.
Does the motor include a holding brake?
It is without holding brake.