Technical Summary
| Motor type | Permanent-magnet synchronous motor; High Dynamic |
|---|---|
| Rated power | PN=2 kW |
| DC link voltage | UDC=600 V |
| Rated speed | 3,000 rpm (100 K) |
| Rated torque | 6.5 Nm (100 K) |
| Encoder | Encoder IC22DQ: incremental Encoder 22 bits, resolution 4194304, encoder-internal 2048 S/R, commutation position 11 bits |
| Interface | DRIVE-CLiQ |
| Mounting | IM B5 (IM V1, IM V3) |
| Cooling | Natural cooling |
| Degree of protection | IP65 |
| Holding brake | Permanent-magnet brake; holding torque 22.0 Nm; DC 24 V ± 10 % |
Key Features
Permanent-magnet synchronous motor with PN=2 kW, UDC=600 V, rated speed of 3,000 rpm and rated torque of 6.5 Nm (100 K).
Encoder IC22DQ provides a 22-bit incremental Encoder with resolution 4194304, encoder-internal 2048 S/R and commutation position 11 bits.
The motor has a DRIVE-CLiQ interface for its Encoder system.
Design acc. to Code I: IM B5 (IM V1, IM V3). It has a rotatable power connector, rotatable signal and power connectors, and an M40 connector size.
Natural cooling and IP65 degree of protection.
Permanent-magnet holding brake with 22.0 Nm holding torque and DC 24 V ± 10 % power supply voltage.
Frequently Asked Questions
What are the rated power, voltage and speed of 1FK7085-4CF71-1DB1?
PN=2 kW, UDC=600 V and rated speed is 3,000 rpm (100 K).
Which Encoder and interface does the motor have?
It has Encoder IC22DQ, a 22-bit incremental Encoder with resolution 4194304, encoder-internal 2048 S/R, commutation position 11 bits and a DRIVE-CLiQ interface.
How is 1FK7085-4CF71-1DB1 mounted and cooled?
It uses IM B5 (IM V1, IM V3) mounting and natural cooling. Its degree of protection is IP65.
Does the motor include a holding brake?
It has a permanent-magnet holding brake with 22.0 Nm holding torque and DC 24 V ± 10 % power supply voltage.