Technical Summary
| Product type | SIMOTICS S synchronous motor |
|---|---|
| PN | 2kW |
| UDC | 600V |
| M0 | 22Nm (100K) |
| NN | 3000rpm |
| Cooling | Naturally cooled |
| Mounting | FRAME SIZE IMB 5 (IM V1, IM V3), FLANGE 1 |
| Feedback | Absolute encoder 32 S/R singletun, 4096 rotation multiturn, with ENDAT interface (ENCODER AM32S/R) |
| Connections | Rotatable power connector; KTY temperature sensor |
| Protection | IP65 DE flange IP67 |
| Brake | Without holding brake |
| Product status | Product cancellation |
Key Features
PN=2kW, UDC=600V, M0=22Nm (100K), and NN=3000rpm.
Absolute encoder with 32 S/R singletun, 4096 rotation multiturn, and ENDAT interface (ENCODER AM32S/R).
KTY temperature sensor and rotatable power connector.
Naturally cooled; FRAME SIZE IMB 5 (IM V1, IM V3) with FLANGE 1.
Shaft with fitted key, tolerance N; without holding brake. Degree of protection: IP65 DE flange IP67.
Frequently Asked Questions
What are the electrical ratings of 1FK7085-4CF71-1GA2?
PN=2kW, UDC=600V, M0=22Nm (100K), and NN=3000rpm.
What encoder is installed on 1FK7085-4CF71-1GA2?
It has an absolute encoder with 32 S/R singletun, 4096 rotation multiturn, and ENDAT interface (ENCODER AM32S/R).
How is 1FK7085-4CF71-1GA2 mounted and cooled?
It is naturally cooled and uses FRAME SIZE IMB 5 (IM V1, IM V3) with FLANGE 1.
Does 1FK7085-4CF71-1GA2 include a holding brake?
It is without a holding brake.
What protection does 1FK7085-4CF71-1GA2 have?
Degree of protection: IP65 DE flange IP67.