Technical Summary
| Product type | SIMOTICS M compact asynchronous motor |
|---|---|
| Rated operating point 1 | 1000 r/min; 3.7 kW; 35 Nm; 10 A; 333 V |
| Rated operating point 2 | 1150 r/min; 4.3 kW; 36 Nm; 10 A; 380 V |
| Rated operating point 3 | 1350 r/min; 4.7 kW; 33 Nm; 9.7 A; 423 V |
| Rated operating point 4 | 1500 r/min; 5.2 kW; 33 Nm; 9.7 A; 470 V |
| Encoder | Incremental SIN/COS 1 VPP, 2048 S/R, with C and D track; encoder IC2048S/R |
| Ventilation and protection | Forced ventilation; air flow direction NDE–> DE; IP55 degree of protection |
| Mounting and connections | DESIGN IM B5 (IMV 1,IM V3); terminal box above; cable entry on the right; signal connection D-end |
Key Features
SIMOTICS M compact asynchronous motor with rated operating points from 1000 r/min to 1500 r/min.
The motor provides 3.7 kW, 35 Nm, 10 A at 1000 r/min and 333 V; 4.3 kW, 36 Nm, 10 A at 1150 r/min and 380 V; 4.7 kW, 33 Nm, 9.7 A at 1350 r/min and 423 V; or 5.2 kW, 33 Nm, 9.7 A at 1500 r/min and 470 V.
Incremental encoder SIN/COS 1 VPP, 2048 S/R, with C and D track; encoder IC2048S/R.
Includes temperature sensor KTY 84-130.
Forced ventilation with air flow direction NDE–> DE and IP55 degree of protection.
DESIGN IM B5 (IMV 1,IM V3), with fitted-key shaft, terminal box above, cable entry on the right, and signal connection at the D-end.
Frequently Asked Questions
What is the exact model and motor type?
The exact model is 1PH8103-1MD12-1BA1, a SIMOTICS M compact asynchronous motor.
What rated operating points does the motor have?
It has 3.7 kW, 35 Nm, 10 A at 1000 r/min and 333 V; 4.3 kW, 36 Nm, 10 A at 1150 r/min and 380 V; 4.7 kW, 33 Nm, 9.7 A at 1350 r/min and 423 V; or 5.2 kW, 33 Nm, 9.7 A at 1500 r/min and 470 V.
What encoder is included?
It has an incremental SIN/COS 1 VPP encoder with 2048 S/R, C and D track, encoder IC2048S/R.
How is the motor cooled and protected?
It has forced ventilation, with air flow direction NDE–> DE, and IP55 degree of protection.
What mounting and connection details apply?
The design is IM B5 (IMV 1,IM V3). The shaft has a fitted key; the terminal box is above, the cable entry is on the right, and the signal connection is at the D-end.