Technical Summary
| Motor type | SIMOTICS M compact asynchronous motor |
|---|---|
| Speed and rating 1 | 1500 r/min; 37 kW; 236 Nm; 78 A; 350 V |
| Speed and rating 2 | 1750 r/min; 41 kW; 224 Nm; 76 A; 400 V |
| Speed and rating 3 | 2000 r/min; 45 kW; 215 Nm; 75 A; 440 V |
| Speed and rating 4 | 2200 r/min; 49.5 kW; 215 Nm; 75 A; 493 V |
| Feedback | Incremental encoder SIN/COS 1 VPP, 2048 S/R, with C and D track; encoder IC2048S/R |
| Temperature sensor | KTY 84-130 |
| Ventilation | Forced ventilation; air flow direction DE–> NDE |
| Protection | IP55 degree of protection |
| Mounting | Design IM B35 (IM V15, (IM V35) |
| Shaft and bearing | Plain shaft without fitted key; standard bearing with fixed bearing |
| Connections | Terminal box above; cable entry on the right; signal connection D-end |
Key Features
SIMOTICS M compact asynchronous motor with 1500 r/min, 37 kW, 236 Nm, 78 A and 350 V.
At 1750 r/min: 41 kW, 224 Nm, 76 A and 400 V; at 2000 r/min: 45 kW, 215 Nm, 75 A and 440 V; at 2200 r/min: 49.5 kW, 215 Nm, 75 A and 493 V.
Incremental SIN/COS 1 VPP encoder with 2048 S/R, C and D track, encoder IC2048S/R, and temperature sensor KTY 84-130.
Forced ventilation with air flow direction DE–> NDE and IP55 degree of protection.
Design IM B35 (IM V15, (IM V35), plain shaft without fitted key, standard bearing with fixed bearing, and vibration severity grade R/A.
Terminal box above, cable entry on the right, and signal connection D-end.
Product cancellation.
Frequently Asked Questions
What ratings does the 1PH8165-1MF03-0BA1 provide?
It provides 37 kW, 236 Nm, 78 A and 350 V at 1500 r/min; 41 kW, 224 Nm, 76 A and 400 V at 1750 r/min; 45 kW, 215 Nm, 75 A and 440 V at 2000 r/min; and 49.5 kW, 215 Nm, 75 A and 493 V at 2200 r/min.
Which feedback device is included?
It has an incremental SIN/COS 1 VPP encoder with 2048 S/R, C and D track, encoder IC2048S/R, and a KTY 84-130 temperature sensor.
How is this motor mounted and configured?
It has design IM B35 (IM V15, (IM V35), a plain shaft without fitted key, and a standard bearing with fixed bearing.
What ventilation and protection does it have?
It has forced ventilation, DE–> NDE air flow direction, and IP55 degree of protection.
What is the product lifecycle status?
Product cancellation.