Product Image Not Available

Email for Product Photos

1PH8224-1MD10-1FA1

1PH8224-1MD10-1FA1 is a SIMOTICS M compact asynchronous motor with 71 kW, 678 Nm, 158 A at 335 V, IP55, and SIN/COS encoder. Request a quote.

Specifications
Product Code 1PH8224-1MD10-1FA1
Weight 610 kg
Lifecycle Product cancellation
Availability in stock
Lead Time Confirmed with quotation

Ask us for a quote or discuss the details before you order.

Back to Category

Product Details

Technical Summary

Motor type SIMOTICS M compact asynchronous motor
Rated operating point 1000 r/min, 71 kW, 678 Nm, 158 A, 335 V
Second operating point 1150 r/min, 81 kW, 673 Nm, 156 A, 385 V
Third operating point 1350 r/min, 92 kW, 651 Nm, 154 A, 450 V
Feedback Incremental encoder SIN/COS 1 VPP, 2048 S/R, with C and D track
Ventilation Forced ventilation; air flow direction NDE–>DE
Protection IP55 degree of protection
Mounting Design IM B3; IMB6, IMB7, IMB8, IMV6
Product lifecycle Product cancellation

Key Features

Compact asynchronous motor
SIMOTICS M motor with 1000 r/min, 71 kW, 678 Nm, 158 A, and 335 V.
Three operating points
1150 r/min: 81 kW, 673 Nm, 156 A, 385 V; 1350 r/min: 92 kW, 651 Nm, 154 A, 450 V.
Incremental encoder
SIN/COS 1 VPP encoder with 2048 S/R and C and D track, encoder IC2048S/R.
Forced ventilation and IP55
Forced ventilation has air flow direction NDE–>DE, with IP55 degree of protection.
Installation and shaft
Design IM B3, with IMB6, IMB7, IMB8, and IMV6; shaft with fitted key and FULL-KEY BALANCING.
Terminal and signal connections
Terminal box is above, cable entry is on the right, and signal connection is D-end.

Frequently Asked Questions

What motor ratings does 1PH8224-1MD10-1FA1 have?

It has 1000 r/min, 71 kW, 678 Nm, 158 A, and 335 V at one operating point; 1150 r/min, 81 kW, 673 Nm, 156 A, and 385 V at another; and 1350 r/min, 92 kW, 651 Nm, 154 A, and 450 V at a third.

Which encoder is installed on 1PH8224-1MD10-1FA1?

It has an incremental SIN/COS 1 VPP encoder with 2048 S/R and C and D track, encoder IC2048S/R.

What mounting designs are supported?

The design is IM B3, with IMB6, IMB7, IMB8, and IMV6.

What protection and ventilation does it have?

It has IP55 degree of protection and forced ventilation with air flow direction NDE–>DE.

Where are the terminal box and cable entry located?

The terminal box is above, and the cable entry is on the right. The signal connection is D-end.

Need a specific manual or datasheet? Send the order number and document reference, if known. Email Us

Request a Quote for This Product

For several items, list the references and quantities in your message.

Fields marked * are required. WhatsApp is optional.

Prefer to send a message? Use email or WhatsApp.